refactor(modbus): switch to native Modbus TCP protocol
Switch from Modbus RTU over TCP to native Modbus TCP based on hardware testing. Uses standard MBAP header (no CRC16), port 502, and TCP-only tokio-modbus feature for simpler implementation. Updated: Cargo.toml, plan.md, research.md, tasks.md
This commit is contained in:
@@ -8,7 +8,7 @@
|
||||
|
||||
**Technical Approach**:
|
||||
- **Architecture**: Pragmatic Balance (Service Layer Pattern) - Hexagonal architecture with domain/application/infrastructure/presentation layers
|
||||
- **Backend**: Rust with tokio-modbus 0.17.0 for Modbus RTU over TCP, Poem 3.1 for HTTP API with OpenAPI
|
||||
- **Backend**: Rust with tokio-modbus 0.17.0 for Modbus TCP, Poem 3.1 for HTTP API with OpenAPI
|
||||
- **Frontend**: Vue 3 + TypeScript with HTTP polling (2-second intervals), deployed to Cloudflare Pages
|
||||
- **Reverse Proxy**: Traefik on Raspberry Pi with Authelia middleware for authentication and HTTPS termination
|
||||
- **Persistence**: SQLite for relay labels
|
||||
@@ -19,7 +19,7 @@
|
||||
|
||||
**Language/Version**: Rust 1.75+
|
||||
**Primary Dependencies**:
|
||||
- tokio-modbus 0.17.0 (Modbus RTU over TCP)
|
||||
- tokio-modbus 0.17.0 with TCP feature only (Modbus TCP protocol)
|
||||
- Poem 3.1 + poem-openapi 5.1 (HTTP API with OpenAPI)
|
||||
- Tokio 1.48 (async runtime)
|
||||
- sqlx 0.8 (SQLite persistence with compile-time verification)
|
||||
@@ -184,7 +184,7 @@ sta/ (repository root)
|
||||
**Action**: Add the following dependencies:
|
||||
```toml
|
||||
[dependencies]
|
||||
tokio-modbus = { version = "0.17.0", features = ["rtu", "tcp"] }
|
||||
tokio-modbus = { version = "0.17.0", default-features = false, features = ["tcp"] }
|
||||
sqlx = { version = "0.8", features = ["runtime-tokio", "sqlite"] }
|
||||
mockall = "0.13"
|
||||
async-trait = "0.1"
|
||||
@@ -904,7 +904,7 @@ impl RelayLabelRepository for SqliteRelayLabelRepository {
|
||||
|
||||
### Phase 4: Infrastructure - Real Modbus Client (1.5 days)
|
||||
|
||||
**Objective**: Implement real Modbus RTU over TCP communication using tokio-modbus.
|
||||
**Objective**: Implement real Modbus TCP communication using tokio-modbus.
|
||||
|
||||
**Prerequisites**: Phase 1 complete (controller trait), hardware available for testing
|
||||
|
||||
@@ -2014,7 +2014,7 @@ tests/
|
||||
```toml
|
||||
[dependencies]
|
||||
# Existing dependencies...
|
||||
tokio-modbus = { version = "0.17.0", features = ["rtu", "tcp"] }
|
||||
tokio-modbus = { version = "0.17.0", default-features = false, features = ["tcp"] }
|
||||
sqlx = { version = "0.8", features = ["runtime-tokio", "sqlite"] }
|
||||
mockall = "0.13"
|
||||
async-trait = "0.1"
|
||||
|
||||
@@ -67,10 +67,11 @@
|
||||
|
||||
**Version**: tokio-modbus 0.17.0 (latest stable, released 2025-10-22)
|
||||
|
||||
**Protocol**: Modbus RTU over TCP (NOT Modbus TCP)
|
||||
- Hardware uses RTU protocol tunneled over TCP
|
||||
- Includes CRC16 validation
|
||||
- Different from native Modbus TCP (no CRC, different framing)
|
||||
**Protocol**: Modbus TCP (native TCP protocol)
|
||||
- Hardware configured to use native Modbus TCP protocol
|
||||
- Uses MBAP (Modbus Application Protocol) header
|
||||
- No CRC16 validation (TCP/IP handles error detection)
|
||||
- Standard Modbus TCP protocol on port 502
|
||||
|
||||
**Connection Strategy**:
|
||||
- Shared `Arc<Mutex<Context>>` for simplicity
|
||||
@@ -92,11 +93,13 @@
|
||||
|
||||
### Critical Gotchas
|
||||
|
||||
1. **Device Gateway Configuration**: Hardware MUST be set to "Multi-host non-storage type" - default storage type sends spurious queries causing failures
|
||||
1. **Device Protocol Configuration**: Hardware MUST be configured to use Modbus TCP protocol (not RTU over TCP) via VirCom software
|
||||
- Set "Transfer Protocol" to "Modbus TCP protocol" in Advanced Settings
|
||||
- Device automatically switches to port 502 when TCP protocol is selected
|
||||
|
||||
2. **No Built-in Timeouts**: tokio-modbus has NO automatic timeouts - must wrap every operation with `tokio::time::timeout`
|
||||
2. **Device Gateway Configuration**: Hardware MUST be set to "Multi-host non-storage type" - default storage type sends spurious queries causing failures
|
||||
|
||||
3. **RTU vs TCP Confusion**: Device uses Modbus RTU protocol over TCP (with CRC), not native Modbus TCP protocol
|
||||
3. **No Built-in Timeouts**: tokio-modbus has NO automatic timeouts - must wrap every operation with `tokio::time::timeout`
|
||||
|
||||
4. **Address Indexing**: Relays labeled 1-8, but Modbus addresses are 0-7 (use newtype pattern with conversion methods)
|
||||
|
||||
@@ -111,8 +114,8 @@
|
||||
use tokio_modbus::prelude::*;
|
||||
use tokio::time::{timeout, Duration};
|
||||
|
||||
// Connect to device
|
||||
let socket_addr = "192.168.1.200:8234".parse()?;
|
||||
// Connect to device using Modbus TCP on standard port 502
|
||||
let socket_addr = "192.168.1.200:502".parse()?;
|
||||
let mut ctx = tcp::connect(socket_addr).await?;
|
||||
|
||||
// Set slave ID (unit identifier)
|
||||
@@ -125,6 +128,8 @@ let states = timeout(
|
||||
).await???; // Triple-? handles timeout + transport + exception errors
|
||||
```
|
||||
|
||||
**Note**: Modbus TCP uses the standard MBAP header and does not require CRC16 validation. The protocol is cleaner and more standardized than RTU over TCP.
|
||||
|
||||
**Toggle Relay with Retry**:
|
||||
```rust
|
||||
async fn toggle_relay(
|
||||
|
||||
@@ -13,25 +13,25 @@
|
||||
**Purpose**: Initialize project dependencies and directory structure
|
||||
|
||||
- [x] **T001** [Setup] [TDD] Add Rust dependencies to Cargo.toml
|
||||
- Add: tokio-modbus = "0.17.0", sqlx = { version = "0.8", features = ["runtime-tokio", "sqlite"] }, mockall = "0.13", async-trait = "0.1"
|
||||
- Add: tokio-modbus = { version = "0.17.0", default-features = false, features = ["tcp"] }, sqlx = { version = "0.8", features = ["runtime-tokio", "sqlite"] }, mockall = "0.13", async-trait = "0.1"
|
||||
- **Test**: cargo check passes
|
||||
- **Complexity**: Low | **Uncertainty**: Low
|
||||
|
||||
- [ ] **T002** [P] [Setup] [TDD] Create module structure in src/
|
||||
- [x] **T002** [P] [Setup] [TDD] Create module structure in src/
|
||||
- Create: src/domain/, src/application/, src/infrastructure/, src/presentation/
|
||||
- **Test**: Module declarations compile without errors
|
||||
- **Complexity**: Low | **Uncertainty**: Low
|
||||
|
||||
- [ ] **T003** [P] [Setup] [TDD] Update settings.rs with Modbus configuration
|
||||
- Add ModbusSettings struct with host, port, slave_id, timeout_secs fields
|
||||
- Add RelaySettings struct with label_max_length field
|
||||
- Add ModbusSettings struct with `host`, `port`, `slave_id`, `timeout_secs` fields
|
||||
- Add RelaySettings struct with `label_max_length` field
|
||||
- Update Settings struct to include modbus and relay fields
|
||||
- **Test**: Settings loads from settings/base.yaml with test Modbus config
|
||||
- **Complexity**: Low | **Uncertainty**: Low
|
||||
|
||||
- [ ] **T004** [P] [Setup] [TDD] Create settings/base.yaml with Modbus defaults
|
||||
- Add modbus section: host: "192.168.1.100", port: 502, slave_id: 1, timeout_secs: 3
|
||||
- Add relay section: label_max_length: 50
|
||||
- Add modbus section: host: "192.168.0.200", port: 502, slave_id: 0, timeout_secs: 5
|
||||
- Add relay section: label_max_length: 8
|
||||
- **Test**: Settings::new() loads config without errors
|
||||
- **Complexity**: Low | **Uncertainty**: Low
|
||||
|
||||
@@ -184,9 +184,9 @@
|
||||
|
||||
- [ ] **T024** [US1] [TDD] Write tests for ModbusRelayController
|
||||
- **REQUIRES HARDWARE/MOCK**: Integration test with tokio_modbus::test utilities
|
||||
- Test: Connection succeeds with valid config
|
||||
- Test: Connection succeeds with valid config (Modbus TCP on port 502)
|
||||
- Test: read_state() returns correct coil value
|
||||
- Test: write_state() sends correct Modbus command
|
||||
- Test: write_state() sends correct Modbus TCP command (no CRC needed)
|
||||
- **File**: src/infrastructure/modbus/modbus_controller.rs
|
||||
- **Complexity**: High → DECOMPOSED below
|
||||
- **Uncertainty**: High
|
||||
@@ -198,6 +198,7 @@
|
||||
**Complexity**: High → Broken into 6 sub-tasks
|
||||
**Uncertainty**: High
|
||||
**Rationale**: Nested Result handling, Arc<Mutex> synchronization, timeout wrapping
|
||||
**Protocol**: Native Modbus TCP (MBAP header, no CRC16 validation)
|
||||
|
||||
- [ ] **T025a** [US1] [TDD] Implement ModbusRelayController connection setup
|
||||
- Struct: ModbusRelayController { ctx: Arc<Mutex<Context>>, timeout_duration: Duration }
|
||||
@@ -219,6 +220,7 @@
|
||||
{
|
||||
use tokio_modbus::prelude::*;
|
||||
|
||||
// Connect using native Modbus TCP protocol (port 502)
|
||||
let socket_addr = format!("{}:{}", host, port)
|
||||
.parse()
|
||||
.map_err(|e| ControllerError::ConnectionError(format!("Invalid address: {}", e)))?;
|
||||
@@ -244,6 +246,7 @@
|
||||
- Private method: read_coils_with_timeout(addr: u16, count: u16) → Result<Vec<bool>, ControllerError>
|
||||
- Wrap ctx.read_coils() with tokio::time::timeout()
|
||||
- Handle nested Result: timeout → io::Error → Modbus Exception
|
||||
- **Note**: Modbus TCP uses MBAP header (no CRC validation needed)
|
||||
- **File**: src/infrastructure/modbus/modbus_controller.rs
|
||||
- **Complexity**: Medium | **Uncertainty**: Medium
|
||||
|
||||
|
||||