application:
port: 3100
version: "0.1.0"
rate_limit:
enabled: true
burst_size: 10
per_seconds: 60
modbus:
feat(application): HealthMonitor service and hardware integration test Add HealthMonitor service for tracking system health status with comprehensive state transition logic and thread-safe operations. Includes 16 unit tests covering all functionality including concurrent access scenarios. Add optional Modbus hardware integration tests with 7 test cases for real device testing. Tests are marked as ignored and can be run with running 21 tests test infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_error_on_failure ... FAILED test infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_timeout_on_slow_device ... FAILED test infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_timeout_on_slow_response ... FAILED test infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_modbus_exception_on_protocol_error ... FAILED test infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_on_when_coil_is_true ... FAILED test infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_propagates_controller_error ... FAILED test infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_off_when_coil_is_false ... FAILED test infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_connection_error_on_io_error ... FAILED test infrastructure::modbus::client::tests::t025a_connection_setup_tests::test_new_with_valid_config_connects_successfully ... ok test infrastructure::modbus::client::tests::t025a_connection_setup_tests::test_new_stores_correct_timeout_duration ... ok test infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_coil_values_on_success ... ok test infrastructure::modbus::client::tests::write_all_states_validation_tests::test_write_all_states_with_9_states_returns_invalid_input ... ok test infrastructure::modbus::client::tests::write_all_states_validation_tests::test_write_all_states_with_empty_vector_returns_invalid_input ... ok test infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_can_toggle_relay_multiple_times ... ok test infrastructure::modbus::client::tests::write_all_states_validation_tests::test_write_all_states_with_8_states_succeeds ... ok test infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_succeeds_for_valid_write ... ok test infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_off_writes_false_to_coil ... FAILED test infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_correctly_maps_relay_id_to_modbus_address ... ok test infrastructure::modbus::client::tests::write_all_states_validation_tests::test_write_all_states_with_7_states_returns_invalid_input ... ok test infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_on_writes_true_to_coil ... ok test infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_correctly_maps_relay_id_to_modbus_address ... ok failures: ---- infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_error_on_failure stdout ---- thread 'infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_error_on_failure' (1157113) panicked at backend/src/infrastructure/modbus/client_test.rs:320:14: Failed to connect: ConnectionError("Connection refused (os error 111)") note: run with `RUST_BACKTRACE=1` environment variable to display a backtrace ---- infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_timeout_on_slow_device stdout ---- thread 'infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_timeout_on_slow_device' (1157114) panicked at backend/src/infrastructure/modbus/client_test.rs:293:14: Failed to connect: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_timeout_on_slow_response stdout ---- thread 'infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_timeout_on_slow_response' (1157112) panicked at backend/src/infrastructure/modbus/client_test.rs:176:14: Failed to connect: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_modbus_exception_on_protocol_error stdout ---- thread 'infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_modbus_exception_on_protocol_error' (1157111) panicked at backend/src/infrastructure/modbus/client_test.rs:227:14: Failed to connect: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_on_when_coil_is_true stdout ---- thread 'infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_on_when_coil_is_true' (1157119) panicked at backend/src/infrastructure/modbus/client_test.rs:354:14: Failed to connect to test server: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_propagates_controller_error stdout ---- thread 'infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_propagates_controller_error' (1157117) panicked at backend/src/infrastructure/modbus/client_test.rs:396:14: Failed to connect to test server: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_off_when_coil_is_false stdout ---- thread 'infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_off_when_coil_is_false' (1157118) panicked at backend/src/infrastructure/modbus/client_test.rs:375:14: Failed to connect to test server: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_connection_error_on_io_error stdout ---- thread 'infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_connection_error_on_io_error' (1157110) panicked at backend/src/infrastructure/modbus/client_test.rs:202:14: Failed to connect: ConnectionError("Connection refused (os error 111)") ---- infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_off_writes_false_to_coil stdout ---- thread 'infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_off_writes_false_to_coil' (1157122) panicked at backend/src/infrastructure/modbus/client_test.rs:508:9: assertion `left == right` failed: Relay should be Off after writing Off state left: On right: Off failures: infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_connection_error_on_io_error infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_modbus_exception_on_protocol_error infrastructure::modbus::client::tests::t025b_read_coils_timeout_tests::test_read_coils_returns_timeout_on_slow_response infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_error_on_failure infrastructure::modbus::client::tests::t025c_write_single_coil_timeout_tests::test_write_single_coil_returns_timeout_on_slow_device infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_propagates_controller_error infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_off_when_coil_is_false infrastructure::modbus::client::tests::t025d_read_relay_state_tests::test_read_state_returns_on_when_coil_is_true infrastructure::modbus::client::tests::t025e_write_relay_state_tests::test_write_state_off_writes_false_to_coil test result: FAILED. 12 passed; 9 failed; 0 ignored; 0 measured; 128 filtered out; finished in 3.27s. Ref: T034, T039, T040 (specs/001-modbus-relay-control/tasks.org)
2026-01-21 20:43:06 +01:00
host: 192.168.0.200
port: 502
slave_id: 0
timeout_secs: 5
relay:
label_max_length: 8